AD8302 Wideband Amplitude Phase Detection Impedance Analysis Module Amplifier Filter Mixer Loss and Phase Measurement

AD8302 Wideband Amplitude Phase Detection Impedance Analysis Module Amplifier Filter Mixer Loss and Phase Measurement

  • R 346.38
    Unit price per 
  • Save R 346.38
Tax included.

SKU:

Feature:

Single chip silicon bipolar device, amplitude / phase measurement
The AD8302 is a fully integrated RF IC that measures the amplitude and phase between two independent input signals. The device operates from low frequencies to 2.7 GHz.
The AD8302 contains two precision-matched wideband log amps, a wideband linear multiplier/phase detector, a 1.8V precision voltage reference, and an analog output proportional operation circuit.
The input signal range is -60 dBm to 0dBm (reference impedance 50Ω) with a corresponding dynamic range of 60dB.
The AD8302 output provides accurate amplitude measurements in the +/-30dB range with a slope of 30mV/dB; a phase measurement range of 0 to 180° with a slope of 10mV/degree.
Note: Please refer to application note AN-691 for module low frequency detection. The AD8302 is available in a 14-pin TSSOP package and operates over a temperature range of -40°C to 85°C.
 
Module application:
 
1. Measurement of insertion loss and phase of an amplifier, filter or mixer
2. Measure the vector reflection coefficient of any load
3. Impedance analysis

Support cable:

BNC male to SMA male
SMA male to SMA male

Frequency Hz Signal source
RMS@50 ohm
Source phase (degrees) Output voltage V
CH1 CH2 CH1 CH2 VM VP
500K 0.2V 0.2V 0 90 0.908V 0.907V
500K 0.1V 0.2V 0 90 0.724V 0.906V
500K 0.2V 0.1V 0 90 1.093V 0.908V
500K 0.2V 0.2V 0 180 0.908V 0.032V
500K 0.2V 0.1V 0 180 1.094V 0.023V
500K 0.1V 0.2V 0 180 0.725V 0.022V
500K 0.2V / 0.2V 0 -90 0.908V 0.915V
500K 0.1V 0.2V 0 -90 0.725V 0.914V
500K 0.2V / 0.1V 0 -90 1.093V 0.915V
500K 0.2V 0.2V 0 -180 0.909V 0.032V
500K 0.2V / 0.1V 0 -180 1.093V 0.022V
500K 0.1V 0.2V 0 -180 0.724V 0.021V

Package includes:

1 x AD8302 module