AC110V/220V to DC24V 10A 250W Switching Power Supply without Fan 200*110*50mm
Tax included.
Feature:
Package includes:
1 x Power supply







| Project | Technical indicators | Unit | Remarks |
| Basic requirements | 24V 10A 250W | 1 | Normal (no fan) |
| Dimensions | 200*110*50 | mm | |
| Operating temperature | -10 ° C ~ +50 ° C, 20% ~ 95% RH (no condensation) | ??/span> | |
| Storage temperature | -20 ° C ~ +85 ° C, 20% ~ 95% RH (no condensation) | ??/span> | |
| Temperature Coefficient | 0.02~0.05%/°C | ||
| Heat dissipation method | Natural cooling | ||
| Rated voltage range | 220VAC | V | AC |
| Input voltage range | 110V/220V | V | AC |
| Input frequency range | 50 to 60 Hz | Hz | Except DC input |
| Input undervoltage protection | 115 to 150% intermittent mode | V | |
| Input undervoltage recovery | Automatic recovery | V | |
| Input overvoltage protection | 115 to 150% intermittent mode | V | |
| Input overvoltage recovery | Automatic recovery | V | |
| electric shock | ≤1% | A | Maximum input voltage full load |
| Machine efficiency | ≤0.5% | % | Rated input full load |
| Output voltage range | 24V ± 0.5% | V | Triple output |
| Output current | 10A | A | Triple output |
| Ripple and noise | ≤150 | mVp-p | |
| Rise Time | ≤50 | ms | |
| Output delay | ≤5 | S | |
| Voltage regulation | ≤0.5 | % | |
| Load adjustment rate | ≤1% | % | |
| Output overcurrent protection | Current drooping | ||
| Output short circuit protection | IGBT | ||
| Output overvoltage protection | Soft start protection | ||
| Insulation resistance input to output | >30MΩ | ||
| Insulation resistance input to the earth | >30MΩ | ||
| Insulation resistance output to the earth | >30MΩ | ||
| Insulation resistance | >50MΩ | ||
| MTBF | 100,000 | H | |
| Annual repair rate | 0.3< | % |