VICIOR VC9705 LCD Digital Multimeter Current Voltage Resistance Tester Meter Auto Power Off
Tax included.
Features:
Specifications:
1.DC voltage(DCV)
Input impedance: 10MΩOverload protection: 200mV range is 550V DC or AC peak;
the rest is 1000V DC or 750V AC peak.
2. AC voltage RMS(ACV)
Input impedance: 10MΩ.Standard sine wave and triangular wave frequency response:40 Hz-1kHz;
other waveform frequency response: 40Hz-200Hz
3.DC current
The maximum measured pressure drop: 200mv Overload protection:200:200mA / 250V speed
Glass Fuse: 10A: 10A / 250V ceramic speed fuse
4.AC current
The maximum measured pressure drop: 200mv.Overload protection: 200mA: 200mA / 250V speed
Glass Fuse: 10A: 10A / 250V ceramic speed fuse
Frequency response:Sine wave and triangular wave is 40HZ-1KZ; other waveform is 40Hz-200Hz;Display: True RMS;
5.Resistance (Q)
measurement; Open circuit voltage: less than 3V; overload protection: 550V DC or AC peak;
A: In the use of 200Ω range, you should first short-circuit test leads, measured lead
resistance, and then subtracted from the real
B: when measures larger than 1MΩ resistance, the slow reading is a normal phenomenon, please read the value after show stability.
6. NCV measurement;
When the dial to the measurement ncv function, the instrument
approached electric field. beep sound changes according to the strength of the electric beep intermittent sounds also from strong. to weak.
7.Capacitance
Overload protection: 550V DC or AC peak
Input sensitivity: 1V RMS; overload protection; 550V DC or AC peak (not more than 10 seconds)
Package Included:
1 x Multimeter
1 x One Pair of Test Leads
Detail Pictures:
1. Display, liquid crystal display (LCD)
2. Maximum display: 1999 (3 1/2) bits Automatic polarity display
3. Measurement: double integral A / D conversion;
4. Sampling rate: about 3 times per second;
5.Over range display: "0L"
6.Low voltage display:symbol appears;
2. Maximum display: 1999 (3 1/2) bits Automatic polarity display
3. Measurement: double integral A / D conversion;
4. Sampling rate: about 3 times per second;
5.Over range display: "0L"
6.Low voltage display:symbol appears;
7.Working environment: (0 ~ 40) ° C, relative humidity <80%;
8. Power Battery supply: 9V.(battery not included)
9. Volume (size): 184 90 46 nm (LWH);10.Weight: about 320g ;
10.Attachment: a manual, a certificate, a box, a pair of pen, K-type thermocouple
8. Power Battery supply: 9V.(battery not included)
9. Volume (size): 184 90 46 nm (LWH);10.Weight: about 320g ;
10.Attachment: a manual, a certificate, a box, a pair of pen, K-type thermocouple
Specifications:
1.DC voltage(DCV)
Accuracy Range |
2000counts | Resolution |
200mV | 0.5%+3 | 0.1mV |
2V | 0.001V | |
20V | 0.01V | |
200V | 0.1V | |
1000V | 0.8%+10 | 1V |
Input impedance: 10MΩOverload protection: 200mV range is 550V DC or AC peak;
the rest is 1000V DC or 750V AC peak.
2. AC voltage RMS(ACV)
Accuracy Range |
2000counts | Resolution |
200mV | 0.8%+5 | 0.1mV |
2V | 1mV | |
20V | 10mV | |
200V | 100mV | |
750V | 1.2%+10 | 1V |
Input impedance: 10MΩ.Standard sine wave and triangular wave frequency response:40 Hz-1kHz;
other waveform frequency response: 40Hz-200Hz
3.DC current
Accuracy Range |
2000counts | Resolution |
20uA | 0.8%+10 | 0.1uA |
2mA | 0.001mA | |
20mA | 2.0%+30 | 0.01A |
200mA | 0.1A | |
10A | 1A |
Glass Fuse: 10A: 10A / 250V ceramic speed fuse
4.AC current
Accuracy Range |
2000counts | Resolution |
20mA | 2.0%+30 | 0.01A |
200mA | 0.1A | |
10A | 1A |
The maximum measured pressure drop: 200mv.Overload protection: 200mA
Glass Fuse: 10A: 10A / 250V ceramic speed fuse
Frequency response:Sine wave and triangular wave is 40HZ-1KZ; other waveform is 40Hz-200Hz;Display: True RMS;
5.Resistance (Q)
Accuracy Range |
2000counts | Resolution |
200Ω | 0.8%+5 | 0.1Ω |
2KΩ | 0.8%+3 | 1Ω |
20KΩ | 10Ω | |
200KΩ | 100Ω | |
2MΩ | 1KΩ | |
20MΩ | 1.0%+25 | 10KΩ |
A: In the use of 200Ω range, you should first short-circuit test leads, measured lead
resistance, and then subtracted from the real
B: when measures larger than 1MΩ resistance, the slow reading is a normal phenomenon, please read the value after show stability.
6. NCV measurement;
When the dial to the measurement ncv function, the instrument
approached electric field. beep sound changes according to the strength of the electric beep intermittent sounds also from strong. to weak.
7.Capacitance
Accuracy Range |
2000counts | Resolution |
20 nF |
3.5%+20 |
10pF |
200nF | 100pF | |
2uF | 1nF | |
20uF | 10nF | |
200uF |
5.0%+10 |
100nF |
2mF | 1uF | |
20mF | 10uF |
Overload protection: 550V DC or AC peak
Input sensitivity: 1V RMS; overload protection; 550V DC or AC peak (not more than 10 seconds)
1 x Multimeter
1 x One Pair of Test Leads