{"product_id":"100a-200a-300a-500a-lcd-combo-meter-voltage-current-kwh-watt-meter-12v-24v-48v-96v-dc120v-battery-capacity-power-monitoring","title":"100A \/200A \/300A\/500A LCD Combo Meter Voltage Current KWh Watt Meter 12V 24V 48V 96V DC120V Battery Capacity Power Monitoring","description":"\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003eIt is a basic multi-function instrument that can display various physical parameters such as voltage, current, power, capacity, energy, and operating time in real time. Overvoltage, undervoltage, overcurrent can be achieved through reserved relay interfaces. . And the meter uses 1.8-inch color LCD as a display, display data more comprehensive, clear and easy to observe. This meter is ideal for applications that require monitoring of the output voltage and current as well as applications such as charging and discharging batteries.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003e Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e1. The bidirectional detection current makes it easy for the user who detects the charge and discharge to detect the bidirectional current without changing the wiring direction.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e2. Power-off memory function, able to memorize the number of AH and WH before power off after power off, which is convenient for observation and measurement.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e3. time and AH number clear function, does not affect the next measurement.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e4. The number of AHs can be filled up without affecting the direct discharge measurement.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e5. voltage, current, charge capacity AH number, WH number, time, power at the same time display, display information is comprehensive and clear.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e6. with output off function keys, flexible open or shut off the output.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e7. with over-voltage, over-current protection.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cspan style=\"font-size:14px;\"\u003e8. when necessary, you can turn off the LCD display, reduce product power\u003c\/span\u003e\u003c\/div\u003e\u003cdiv\u003e \u003c\/div\u003e\u003cp data-spm-anchor-id=\"a2g0o.detail.1000023.i1.4cd616a1XnSvHS\" style='box-sizing: border-box; margin: 0px; font-size: 14px; line-height: inherit; font-family: \"Open Sans\", Arial, Helvetica, sans-serif, Heiti;'\u003e \u003c\/p\u003e\u003cp style='box-sizing: border-box; margin: 0px; font-size: 14px; line-height: inherit; font-family: \"Open Sans\", Arial, Helvetica, sans-serif, Heiti;'\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cspan style='box-sizing: border-box; max-width: 100%; word-break: break-word; font-family: \"times new roman\", times, serif;'\u003e\u003cimg alt=\"1\" data-spm-anchor-id=\"a2g0o.detail.1000023.i0.4cd616a1XnSvHS\" src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1cZ.IjlsmBKNjSZFFq6AT9VXaQ.jpg\" style=\"box-sizing: border-box; border-style: none; vertical-align: middle; max-width: 100%;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style='box-sizing: border-box; margin: 0px; font-size: 14px; line-height: inherit; font-family: \"Open Sans\", Arial, Helvetica, sans-serif, Heiti;'\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cimg alt=\"Z1207\" src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1BUeKAmtYBeNjSspaq6yOOFXaf.jpg\" style=\"box-sizing: border-box; border-style: none; vertical-align: middle; max-width: 100%;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003e1 measured voltage value                                      \u003cbr\u003e2 Measured current value                                        \u003cbr\u003e3 measured power value                                       \u003cbr\u003e4 Accumulated capacity or energy value              \u003cbr\u003e5 Battery Remaining Capacity Progress Bar           \u003cbr\u003e6 percentage of battery remaining capacity\u003cbr\u003e7 Measured temperature\u003ce style=\"color:red;\"\u003e\u003cspan style=\"color:#000000;\"\u003e(\u003c\/span\u003e\u003c\/e\u003e\u003cspan style=\"color:#000000;\"\u003eDefault withTemperature measurement function)\u003c\/span\u003e\u003cbr\u003e8 output status display\u003cbr\u003e9 Total running time\u003cbr\u003e10 Empty\u003c\/span\u003e\u003c\/p\u003e\u003cp style='box-sizing: border-box; margin: 0px; font-size: 14px; line-height: inherit; font-family: \"Open Sans\", Arial, Helvetica, sans-serif, Heiti;'\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eInstructions:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:14px;\"\u003e1. AH, WH display switch, click to switch to display WH number, click to switch to display AH number.\u003cbr\u003e2. Press OK key to enter the system parameter setting interface, then press OK key to switch the type of setting parameter. The set parameters include BAT, BPC, OPP, OVP, LVP, NCP, OCP, OTP, ADS, TTL, CLR, DTE. , Click to change the parameters, after the parameters are set, press OK to exit the parameter setting interface.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eFunction introduction:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e1, \"BAT\" battery capacity value setting, this parameter is to set the battery measured total capacity.\u003cbr\u003e2, \"BPC\" battery remaining capacity percentage, can be set according to the value of the remaining battery AH\u003cbr\u003e\u003cbr\u003e4, \"OVP\" set over-voltage protection value, if the OVP value is set, when the actual measured voltage value is greater than the set value, it will prompt over-voltage, and cut off the relay (self-provisioned).\u003cbr\u003e5, \"LVP\" set over-voltage protection value, if you set the LVP value, when the actual measured voltage value is less than the set value, it will prompt undervoltage, and cut off the relay (self-provisioned).\u003cbr\u003e6, \"NCP\" set over-voltage protection value, if the NCP value is set, when the actual measurement of the charging current value is less than the set value, it will prompt over-current, and cut off the relay (self-provisioned).\u003cbr\u003e7, \"OCP\" set over-voltage protection value, if the OCP value is set, when the actual measurement of discharge current value is less than the set value, it will prompt over-current, and cut off the relay (self-provisioned).\u003cbr\u003e8, \"OTP\" set over-temperature protection value, if the OTP value is set, when the actual measured temperature value is greater than the set value, it will prompt the temperature, and cut off the relay (self-provisioned \u003ce style=\"color:red;\"\u003e\u003cspan style=\"color:#000000;\"\u003e,\u003c\/span\u003e\u003c\/e\u003eDefault without Temperature measurement function).\u003cbr\u003e9, \"ADS\" communication address code settings. In multi-machine communication, multi-machine communication is achieved by setting the address code.\u003cbr\u003e10, \"TTL\" instrument default relay output power state, normally open or normally closed.\u003cbr\u003e11, \"CLR\" no-load current clear function, if the actual no-load current is zero\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003eConnection mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003e1) its own power supply wiring diagram\u003c\/span\u003e\u003c\/p\u003e\u003cp style='box-sizing: border-box; margin: 0px; font-size: 14px; line-height: inherit; font-family: \"Open Sans\", Arial, Helvetica, sans-serif, Heiti;'\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word; color: rgb(46, 48, 51); font-family: arial, sans-serif; line-height: 20px; background-color: rgb(238, 240, 242);\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cimg alt=\"Z1208\" src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1Wz2_z3aTBuNjSszfq6xgfpXaF.jpg\" style=\"box-sizing: border-box; border-style: none; vertical-align: middle; max-width: 100%;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003eNote: If the voltage range of the tested battery (power supply) is between (6-75V) during the normal operation, it can use its own power supply wiring mode. First, adjust the jumper cap of the power supply selection interface to “2W”, and then connect it. The positive pole of the battery (power supply) is connected to the voltage measurement port “Bat+”, and the negative pole of the battery (power supply) is connected to the shunt “BAT-”. The positive and negative poles of the power supply should not be connected wrongly or reversed. Connect the positive pole of the battery (power supply) to the positive pole of the load, and connect the negative pole of the battery (power supply) to the negative pole of the load through the other end of the shunt; the positive pole of the charger is connected to the positive pole of the battery, and the negative pole of the charger passes through the shunt. One end is connected to the battery (power supply).\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003e(2) External power supply wiring diagram\u003c\/span\u003e\u003c\/p\u003e\u003cp style='box-sizing: border-box; margin: 0px; font-size: 14px; line-height: inherit; font-family: \"Open Sans\", Arial, Helvetica, sans-serif, Heiti;'\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cimg alt=\"Z1209\" src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1qh7dewZC2uNjSZFnq6yxZpXaz.jpg\" style=\"box-sizing: border-box; border-style: none; vertical-align: middle; max-width: 100%;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style='box-sizing: border-box; margin: 0px; font-size: 14px; line-height: inherit; font-family: \"Open Sans\", Arial, Helvetica, sans-serif, Heiti;'\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003eNote: If the voltage range of the tested battery (power supply) during normal operation is not between (6-75V), the external power supply connection mode can be used. The external power supply voltage range is (6-75)V. The power supply selection interface jumper cap is firstly used. Adjust to \"3W\", then connect the positive terminal of the battery (power supply) to the voltage measurement port \"Bat+\" at the time of connection, connect the negative pole of the battery (power supply) to the shunt \"BAT-\", and the positive and negative poles of the power supply should not be connected. Wrong or reversed. Connect the positive pole of the battery (power supply) to the positive pole of the load, and connect the negative pole of the battery (power supply) to the negative pole of the load through the other end of the shunt; the positive pole of the charger is connected to the positive pole of the battery, and the negative pole of the charger passes through the shunt. One end is connected to the negative pole of the battery (power supply) phase.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003e3) Electrical relay wiring instructions\u003c\/span\u003e\u003c\/p\u003e\u003cp style='box-sizing: border-box; margin: 0px; font-size: 14px; line-height: inherit; font-family: \"Open Sans\", Arial, Helvetica, sans-serif, Heiti;'\u003e\u003cspan style=\"font-size:14px;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cspan style=\"box-sizing: border-box; max-width: 100%; word-break: break-word;\"\u003e\u003cspan style='box-sizing: border-box; max-width: 100%; word-break: break-word; font-family: \"times new roman\", times, serif;'\u003e\u003cimg alt=\"1\" src=\"https:\/\/ae01.alicdn.com\/kf\/HTB1XUMWjGQoBKNjSZJnq6yw9VXay.jpg\" style=\"box-sizing: border-box; border-style: none; vertical-align: middle; max-width: 100%;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp style='box-sizing: border-box; margin: 0px; font-size: 14px; line-height: inherit; font-family: \"Open Sans\", Arial, Helvetica, sans-serif, Heiti;'\u003e \u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:14px;\"\u003eNote: The relay's working power is provided by an external power supply. If the relay is connected, an external power supply with the same working voltage as the relay must be provided, and the power supply status of the instrument is adjusted to the “3W” state. Connect the control port of the relay to the interface of the controller, and then connect the negative pole of the power supply to the “BAT-” position of the shunt through the normally open or normally closed port of the relay, and the wiring of other parts will not change.\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:16px;\"\u003e\u003cstrong\u003ePackage Included:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e1 x \u003c\/span\u003e\u003cspan style=\"\"\u003e100A \/200A \/300A\/500A LCD Combo Meter\u003c\/span\u003e\u003c\/p\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/57\/C2\/14572677-89b1-4884-b951-183d5c5b1f37.jpg\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/3C\/DE\/948f5821-7db1-4aa5-a360-13fe995d7d99.jpg\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/10\/90\/137fe40c-3d64-4fd0-a5fa-e6ed5be51749.JPG\"\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"https:\/\/imgaz.staticbg.com\/images\/oaupload\/ser1\/banggood\/images\/53\/74\/82dc0111-c826-4663-becb-05c8969f25fd.JPG\"\u003e","brand":"Electronic Pro","offers":[{"title":"100A","offer_id":35566920761500,"sku":"1569065","price":1281.12,"currency_code":"ZAR","in_stock":true},{"title":"200A","offer_id":35566920794268,"sku":"1569065","price":1300.0,"currency_code":"ZAR","in_stock":true},{"title":"300A","offer_id":35566920827036,"sku":"1569065","price":1400.0,"currency_code":"ZAR","in_stock":true},{"title":"500A","offer_id":35566920859804,"sku":"1569065","price":1500.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2787\/9162\/products\/b7c0e041-3675-4779-820b-75f55e0ea7e1.jpg?v=1597670473","url":"https:\/\/www.electronicpro.co.za\/products\/100a-200a-300a-500a-lcd-combo-meter-voltage-current-kwh-watt-meter-12v-24v-48v-96v-dc120v-battery-capacity-power-monitoring","provider":"Electronic Pro ","version":"1.0","type":"link"}